METRODATA NetTESTER FAMILY USER MANUAL
76-02-107 Rev.A
Page 91 of 133
The upper limit sets the maximum result (in bytes) that will be tested. For a
meaningful result, this must a value at which the test is known to fail.
14.2.6.4 Test Parameters (Y.1564)
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters
TEST PARAMETERS
Regime Y.1564
traIning <menu>
SLA <menu>
frame siZe/mix abceg (64,128,256,1024,1518)
colour-Aware No
Stop on fail Yes
coNfiguration test <menu>
perfOrmance test <menu>
14.2.6.4.1
Frame Size / Mix
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters /
F
rame size/mix
Values may be entered in letter or number format (see section14.2.6.2.1).
14.2.6.4.2
User Defined Size
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters /
U
ser-Defined size
The user defined frame size defaults to 1518 bytes but may be set to any value
between 64 and the MTU.
14.2.6.4.3
Colour Aware
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters / colour-
A
ware
The tests may be run in colour-aware or non-colour-aware mode, as described in the
Y.1564 document.
In colour-aware mode, the tester will generate separate green and yellow data
streams during the EIR, EBS and Performance tests.
Note that a colour-marking mechanism must be available to run in colour-aware
mode (ie. test traffic must be tagged).
14.2.6.4.4
Stop on Fail
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters /
S
top on fail
This config item will cause the Y.1564 test to stop if any test fails. This is useful
when longer test periods are used such that a configuration error may be discovered
and corrected quickly.
14.2.6.4.5
Configuration Test
Menu Tree: Main Set-Up /
T
esting /
S
AM Tester /
T
est Parameters / Co
N
figuration Test