1. Install the manifold gauge set.
2. Connect the tap pin side of the charging hose to the air purge valve of the manifold gauge.
3. Connect the vacuum pump hose to the center joint of the manifold gauge.
4. Connect the vacuum pump hose to the vacuum pump.
5. Connect the charging hose to the refrigerant tank.
6. Place the refrigerant tank on the scale.
Fig. 3: Connecting Vacuum Pump Hose To Center Joint Of Manifold Gauge
Courtesy of MAZDA MOTORS CORP.
7. Open all the valves of the manifold gauge.