Fig. 9: View Of High & Low-Pressure Side Manifold Gauge Set
Courtesy of MAZDA MOTORS CORP.
20. Start the engine and actuate the A/C compressor.
21. Open the low-pressure side valve of the manifold gauge and charge with refrigerant until the weight of
the refrigerant tank has decreased
450 g {15.9 oz}
from the amount in Step 13.
22. Close the low-pressure side valve of the manifold gauge and the valve of the refrigerant tank.
23. Stop the engine and A/C compressor.
24. Inspect for leakage using a gas leak tester.
If there is no leakage, go to Step 26.
If leakage is found at a loose joint, tighten the joint, then go to next step.