592
Matrix ETERNITY NE System Manual
Dynamic Lock
What's this?
Dynamic Lock allows extension users to change the Toll Control Levels (Calling Permissions) of their extensions on
their own by dialing a code.
The System Administrator/Operator can also change the Toll Control Levels of extensions using Dynamic Lock.
With this feature, extension users can prevent misuse of outgoing call facility from their extensions, especially in
their absence.
There are four types of Toll Control Levels, starting from Level 0 to Level 3 that can be set for extension phones.
For each Toll Control Level from 0 to 3, a 'Call Privilege’
56
is to be assigned and corresponding number strings to
be allowed and number strings to be denied for each Call Privilege are to be configured.
•
Toll Control - Level 0
is Time Zone based, wherein the Call Privilege Type must be defined for the
Day
(working hours) and the
Night
(non-working hours). For instance, you may define 'All Calls' as Call
Privilege for the Day, and 'No Calls' as Call Privilege for the Night.
By default, Call Privilege 'All Calls' is selected for the Day and Night.
•
Toll Control - Level 1
is not based on Time Zones. By default, the Call Privilege Type for this level is
'Local Calls'.
•
Toll Control - Level 2
is not based on Time Zones. By default, the Call Privilege type set for this level is
'National Calls'.
•
Toll Control - Level 3
is not based on Time Zones. By default, Call Privilege 'No Calls' is selected for this
level.
The Call Privilege for each of the above Toll Control Levels can be redefined according to user
requirements.
For example, Toll Control Level 3 can be redefined for allowing all types of calls by selecting 'All Calls' as
Call Privilege Type for
Calls allowed for Lock Level 3
. Similarly, you can configure Level 0 to allow Local
Calls and configure the Local Number strings in the list of Local Numbers.
Refer the feature description for
“Toll Control”
to know more.
Extension users who are allowed the Dynamic Lock feature in their Class of Service, can set the Toll
Control Level in two ways:
•
Manually:
the extension users change the Toll Control Level of the extension whenever they wants by
dialing the feature access code.
For example, an extension user having Toll Control Level 2 (default: National calls) can restrict long
distance dialing on the extension by setting the Toll Control Level to 1 (default: Local calls) before
56.
The Call Privilege types are: No Calls, Local Calls, Regional Calls, National Calls, Limited Calls, All Calls.
Summary of Contents for ETERNITY NE
Page 1: ...ETERNITY NE System Manual ...
Page 2: ......
Page 3: ...ETERNITY NE The Next Generation IP PBX for Small Businesses System Manual ...
Page 10: ...vi Table of Contents ...
Page 24: ...14 Matrix ETERNITY NE System Manual ETERNITY NE3 ETERNITY NE ...
Page 26: ...16 Matrix ETERNITY NE System Manual ...
Page 60: ...50 Matrix ETERNITY NE System Manual ...
Page 260: ...250 Matrix ETERNITY NE System Manual ...
Page 292: ...282 Matrix ETERNITY NE System Manual ...
Page 298: ...288 Matrix ETERNITY NE System Manual Click the more link to expand options ...
Page 373: ...Matrix ETERNITY NE System Manual 363 Click Hardware to expand options ...
Page 884: ...874 Matrix ETERNITY NE System Manual ...
Page 912: ...902 Matrix ETERNITY NE System Manual ...