215676
373
Revision A
1009941
A
B
Figure 5.97: Coolant Recovery Tank
4.
Remove cap (A) from coolant recovery tank (B).
5.
Add coolant at a rate not exceeding 3 gallons per minute
until the recovery tank is half full.
DANGER
Never start or move the machine until you are sure that all
bystanders have cleared the area.
6.
Start the engine. Allow the engine to run at high idle for
approximately 20 minutes or until the engine temperature
reaches 85°C (185°F).
7.
Check the coolant level again. Add coolant until the
recovery tank is half full.
8.
Replace cap (A).
9.
Close the platform. For instructions, refer to
.
10. Close the hood. For instructions, refer to
Maintaining Engine Cooling Box
The windrower engine cooling box components should be cleaned daily, and more frequently in severe dust conditions.
Refer to the following list of procedures before attempting to perform maintenance on the engine cooling box
components:
•
Opening Cooler Box Screen, page 373
•
•
Cleaning Screens and Coolers, page 374
•
Cleaning Cooler Box Components, page 376
•
Adjusting Screen Cleaner Rotor to Screen Clearance, page 377
•
Closing Cooler Box Screen, page 378
Opening Cooler Box Screen
You will need to open the cooler box screen to be able to clean the cooler box.
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator
’
s seat for any reason.
1.
Shut down the engine, and remove the key from the ignition.
2.
Open the hood. For instructions, refer to