215676
369
Revision A
1030164
A
Figure 5.90: Engine Coolant Tank
4.
Ensure coolant recovery tank (A) is one-half full. To add
coolant, refer to
5.
Close the platform. For instructions, refer to
.
6.
Close the hood. For instructions, refer to
.
Changing Coolant
The windrower
’
s coolant should be drained and the cooling system flushed and filled with new coolant according to the
interval specified in the maintenance schedule.
To change the coolant, refer to the following procedures:
•
Draining and Cleaning Coolant Tank, page 369
•
Draining and Cleaning Coolant Tank
Once the coolant has been drained from the cooling system, the system should be flushed and cleaned before being
refilled with coolant.
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator
’
s seat for any reason.
CAUTION
To avoid personal injury from hot coolant, do NOT attempt to open the radiator cap until the engine cools.
1.
Shut down the engine, and remove the key from the ignition.
2.
Open the hood to the highest position. For instructions, refer to
.
3.
Move the platform on the left cab-forward side of the machine to the open position. For instructions, refer to
.