Calibrating Header Float Sensors
The header float sensors can be calibrated by accessing the cab display module
’
s (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensors to be correctly calibrated.
NOTE:
•
The header must be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header. For more information, refer to
4.5 Attaching and Detaching Headers, page
.
•
Use the left or right FLOAT buttons on the CDM to perform this procedure.
WARNING
Check to be sure all bystanders have cleared the area.
1021948
A
Figure 3.152: Float Pin
–
Right Side
IMPORTANT:
Ensure that float pins (A) are installed in the working position.
1009099
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
Figure 3.153: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
•
WINDROWER SETUP? will appear on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
•
NO/YES will appear on the lower line.