215676
123
Revision A
Calibrating Header Tilt Sensor
The header tilt sensor can be calibrated by accessing the cab display module
’
s (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensor to be correctly calibrated.
NOTE:
•
The header must be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header. Refer to
4.5 Attaching and Detaching Headers, page 215
•
This procedure requires installation of the optional Hydraulic Center-Link (MD #B4650).
•
The engine must be running to perform this procedure.
WARNING
Check to be sure all bystanders have cleared the area.
1009099
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
Figure 3.148: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
•
WINDROWER SETUP? will appear on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
•
NO/YES will appear on the lower line.
1018666
HDR TILT SENSOR CAL
EXTEND TILT TO START
CXXX
MXXX
C
B
A
Figure 3.149: Header Tilt Calibration
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT will appear in the upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER TILT
appears on the lower line. Press SELECT (C).
•
HDR TILT SENSOR CAL will appear on the upper line.
•
EXTEND TILT TO START will appear on the lower line.