215676
124
Revision A
1023731
A
Figure 3.150: Header Tilt Controls on GSL
6.
Press and hold HEADER TILT EXTEND button (A) on the
ground speed lever (GSL).
•
CALIBRATING TILT will appear on the upper line.
•
EXTEND TILT HOLD will appear on the lower line.
NOTE:
The word HOLD will flash during calibration. HEADER TILT
DONE will display on the lower line once calibration is
complete.
7.
Release HEADER TILT EXTEND button (A).
•
HEADER TILT SENSOR CAL will appear on the upper line.
•
PRESS RETRACT TILT will appear on the lower line.
1023732
A
Figure 3.151: Header Tilt Controls on GSL
8.
Press and hold HEADER TILT RETRACT button (A) on
the GSL.
•
CALIBRATING TILT will appear on the upper line.
•
RETRACT TILT HOLD will appear on the lower line.
NOTE:
The word HOLD will flash during calibration. HEADER TILT
COMPLETE will display on the lower line once calibration is
complete.
9.
Release HEADER TILT RETRACT button (A).
•
TO CALIBRATE SELECT will appear on the upper line.
•
HEADER TILT will appear on the lower line.
10. Press the right arrow to select the next header sensor calibration or select STOP & EXIT. Press SELECT.
For instructions, refer to
Calibrating Header Height Sensor, page 121
or
Calibrating Header Float Sensors, page 125
.
11. Press PROGRAM to exit programming mode.