215676
142
Revision A
1009288
CXXX
MXXX
DIAGNOSTIC MODE?
NO/YES
A
B
Figure 3.193: Diagnostic Functions
3.
Press SELECT (B) until DIAGNOSTIC MODE? appears on the
upper line.
•
NO/YES will appear on the lower line.
4.
Press right arrow (A) to select YES. Press SELECT (B).
1009330
CXXX
MXXX
ACTIVATE FUNCTIONS?
NO/YES
B
A
Figure 3.194: M155 Functions
5.
Press SELECT (B) until ACTIVATE FUNCTIONS? appears on
the upper line.
•
NO/YES will appear on the lower line.
6.
Press right arrow (A) to select YES. Press SELECT (B).
•
ACTIVATE HEADER HT will appear on the upper line.
1009332
CXXX
MXXX
DRAPER DRV SPD XXXX
D 0 P 0
- +
D
D
B
A
C
E
Figure 3.195: Draper Drive
7.
Press SELECT (E) until DRAPER DRV SPD XXXX appears on
the upper line.
8.
Press and hold HAZARD button (C).
•
Press left arrow (B) to decrease the draper speed.
•
Press right arrow (D) to increase the draper speed.
IMPORTANT:
Do
NOT
overspeed the drapers.
NOTE:
Ensure that the draper drive is working properly.
9.
Release the HAZARD (C) button. The drapers will stop.
10. Press PROGRAM (A) to exit programming mode or press
SELECT (E) to proceed to the next header function option.