Cab-Forward, Engine Running, Header Engaged, Auger Header Attached, Index Switch OFF
These are the messages which can appear in the cab display module (CDM) when the windrower is in cab-forward mode,
the engine is running, the attached auger header is engaged, and the header index switch is set to the OFF state.
Display (Lower or Upper Line)
Description
#####.# ENGINE HRS
Displays the total engine operating time
#####.# UNIT HRS
Displays the windrower
’
s total operating time
#####.# HEADER HRS
Displays the header
’
s total operating time
##.# ACRES/HOUR
##.# HECTARES/HOUR (if Metric)
Displays the actual cutting rate in acres or hectares per hour
###.# SUB ACRES
###.# SUB HECTARES (if Metric)
Displays the total area cut since the last reset was performed. To reset
this value: set the CDM to display SUB ACRES on the lower line, then
hold down the PROGRAM switch for five to seven seconds until the
display resets
###### TOTAL ACRES
###### TOTAL HECT (if Metric)
Displays the total area cut by the machine
##.## REEL RPM
##.## REEL SENSOR
Displays the reel
’
s rotational speed in rpm
This message appears if the reel speed sensor is disabled. The messages
RPM and SENSOR appear alternately at one-second intervals
##.# AUGER SPEED
Displays the auger
’
s rotational speed (4.7
–
9.9)
#### KNIFE SPEED
#### KNIFE SENSOR
Displays the knife speed in strokes per minute
This message appears if the knife speed sensor is disabled. The
messages SPEED and SENSOR appear alternately at one-second intervals
##.# HEADER HEIGHT
##.# HEADER SENSOR
Displays the distance setting (00.0
–
10.0) between the cutterbar and the
ground
This message appears if the header height sensor is disabled. The
messages HEIGHT and SENSOR appear alternately at one-second
intervals
##.# HEADER ANGLE
##.# HEADER SENSOR
Displays the angle setting (00.0
–
10.0) of the header relative to the
ground
This message appears if the header angle sensor is disabled. The
messages ANGLE and SENSOR appear alternately at one-second intervals
##.# L FLOAT R ##.#
FLOAT SENS DISABLED
Displays the left and right float settings (0.0
–
10.0)
This message appears if the float sensor is disabled
LOAD|
■■■■
| | ####
This bar graph represents the hydraulic operating pressure of the circuit
in which the hydraulic pressure sensor is installed. The bars will appear
to be full if the preprogrammed overload pressure (17,237
–
34,474 kPa
[2500
–
5000 psi]). is reached. If the hydraulic pressure sensor is disabled,
this message will not appear
9
### °C or F HYD OIL TEMP
### °C or F HYD TEMP
Displays the temperature of the hydraulic oil
This message appears if the temperature sensor is disabled. The
messages TEMP and SENSOR appear alternately at one-second intervals
##.# VOLTS
Displays the engine electrical system
’
s operating voltage
9.
A sensor which can monitor the knife/conditioner circuit pressure can be installed as an optional kit. To monitor the
hydraulic pressure of the reel/auger circuit, relocate the sensor per kit instruction MD #169031; this instruction is
available from your MacDon Dealer.