J1939
SPN
J1939
FMI
Lamp
Fault
Code
J1939 SPN Description
Cummins Description
2
Amber
3228
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx sensor – data erratic,
intermittent or incorrect
4
Amber
1885
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx sensor circuit –
voltage below normal, or shorted to low source
9
Amber
3232
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx sensor – abnormal
update rate
10
Amber
3725
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx sensor – abnormal
rate of change
13
Amber
3718
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx – out of calibration
16
Amber
3726
Aftertreatment 1 Intake
NOx
Aftertreatment 1 Intake NOx – Data Valid But
Above Normal Operating Range – Moderately
Severe Level
3216
20
Amber
3748
Aftertreatment 1 intake
NOx
Aftertreatment 1 intake NOx sensor – data not
rational – drifted high
3218
2
Amber
3682
Aftertreatment 1 intake
gas sensor power status
Aftertreatment 1 intake NOx sensor power supply
– data erratic, intermittent or incorrect
2
Amber
1694
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor – data erratic,
intermittent or incorrect
4
Amber
1887
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor circuit – voltage
below normal, or shorted to low source
9
Amber
2771
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor – abnormal
update rate
10
Amber
3545
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor – abnormal
rate of change
13
Amber
3717
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor – out of
calibration
3226
20
Amber
3749
Aftertreatment 1 outlet
NOx
Aftertreatment 1 outlet NOx sensor – data not
rational – drifted high
3228
2
Amber
3681
Aftertreatment 1 outlet
gas sensor power status
Aftertreatment 1 outlet NOx sensor power supply –
data erratic, intermittent or incorrect
3246
3
Amber
3319
Aftertreatment 1 diesel
particulate
fi
lter outlet
gas temperature
Aftertreatment 1 diesel particulate
fi
lter outlet
temperature sensor circuit – voltage above normal,
or shorted to high source
2
Amber
2976
Aftertreatment 1 diesel
exhaust
fl
uid supply
module
Aftertreatment 1 diesel exhaust
fl
uid supply module
temperature – data erratic, intermittent or incorrect
3
Amber
3558
Aftertreatment 1 diesel
exhaust
fl
uid supply
module
Aftertreatment 1 diesel exhaust
fl
uid supply module
– voltage above normal, or shorted to high source
3361
4
Amber
3559
Aftertreatment 1 diesel
exhaust
fl
uid supply
module
Aftertreatment 1 diesel exhaust
fl
uid supply module
– voltage below normal, or shorted to low source
214053
452
Revision A
Summary of Contents for M1240
Page 29: ...SAFETY 1 11 Safety Sign Locations Figure 1 31 Safety Sign Locations 214053 17 Revision A ...
Page 40: ......
Page 116: ......
Page 246: ......
Page 352: ...MAINTENANCE AND SERVICING Figure 5 175 Main Fuse Panel Decal MD 207815 214053 340 Revision A ...
Page 370: ......
Page 388: ......
Page 487: ......