Greasing Procedure
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator’s seat for any reason.
1. To avoid injecting dirt and grit, wipe grease
fi
tting with a clean cloth before greasing.
2. Inject grease through
fi
tting with grease gun until grease over
fl
ows
fi
tting, except where noted. Refer to
Lubricants, Fluids, and System Capacities, page 236
3. Leave excess grease on
fi
tting to keep out dirt.
4. Replace any loose or broken
fi
ttings immediately.
5. If
fi
tting will
NOT
take grease, remove and clean thoroughly. Also clean grease passageway. Replace
fi
tting
if necessary.
Grease Points
Figure 5.49: Grease Points
A - Top Link (2 Places) (Both Sides)
B - Caster Pivot (Both Sides)
C - Caster Wheel Hub (Both Sides)
18
18. Do
NOT
over grease. Use 1 pump of grease.