![background image](http://html.mh-extra.com/html/macdon/m1240/m1240_operators-manual_685727237.webp)
Adjusting Knife Speed Alarm
This adjustment requires the header to be in operation.
1. If RUN SCREEN 1 is not already displayed, press soft
key 1 (A) on the Harvest Performance Tracker (HPT)
to display draper RUN SCREEN 1.
Figure 4.260: Header Run Screen 1
2. Press the scroll knob (A) on the Harvest Performance
Tracker (HPT) or the SELECT button (B) on the ground
speed lever (GSL) to display the QuickMenu system.
Figure 4.261: HPT Scroll Knob and GSL
Select Button
3. Scroll to the KNIFE setting (A) on the QuickMenu
screen, and select it.
Figure 4.262: Auger Header QuickMenu Screen
214053
225
Revision A