![background image](http://html.mh-extra.com/html/macdon/m1240/m1240_operators-manual_685727456.webp)
J1939
SPN
J1939
FMI
Lamp
Fault
Code
J1939 SPN Description
Cummins Description
3
Amber
2375
Engine exhaust
gas recirculation 1
temperature
Exhaust gas recirculation temperature sensor
circuit – voltage above normal, or shorted to high
source
4
Amber
2376
Engine exhaust
gas recirculation 1
temperature
Exhaust gas recirculation temperature sensor
circuit – voltage below normal, or shorted to low
source
15
None
2961
Engine exhaust
gas recirculation 1
temperature
Exhaust gas recirculation temperature – data valid
but above normal operating range – least severe
level
412
16
Amber
2962
Engine exhaust
gas recirculation 1
temperature
Exhaust gas recirculation temperature – data valid
but above normal operating range – moderately
severe level
3
Amber
293
Auxiliary temperature 1
Auxiliary temperature sensor input 1 circuit –
voltage above normal, or shorted to high source
4
Amber
294
Auxiliary temperature 1
Auxiliary temperature sensor input 1 circuit –
voltage below normal, or shorted to low source
441
14
Red
292
Auxiliary temperature 1
Auxiliary temperature sensor input 1 – special
instructions
3
Amber
3765
Auxiliary temperature 2
Auxiliary temperature sensor input 2 circuit –
voltage above normal, or shorted to high source
442
4
Amber
3766
Auxiliary temperature 2
Auxiliary temperature sensor input 2 circuit –
voltage below normal, or shorted to low source
2
Amber
431
Accelerator pedal 1 low
idle switch
Accelerator pedal or lever idle validation switch –
data erratic, intermittent or incorrect
13
Red
432
Accelerator pedal 1 low
idle switch
Accelerator pedal or lever idle validation switch
circuit – out of calibration
558
19
Red
3527
Accelerator pedal 1 low
idle switch
Accelerator pedal or lever idle validation switch –
received network data in error
9
Amber
3488
Anti-lock braking (ABS)
active
Anti-lock braking (ABS) controller – abnormal
update rate
563
31
None
4215
Anti-lock braking (ABS)
active
Anti-lock braking (ABS) active – condition exists
611
2
Amber
523
System diagnostic code
#1
Auxiliary intermediate (PTO) speed switch
validation – data erratic, intermittent or incorrect
612
2
Red
115
System diagnostic code
#2
Engine magnetic speed/position lost both of two
signals – data erratic, intermittent or incorrect
625
9
Red
291
Proprietary datalink
Proprietary datalink error (OEM/vehicle datalink)
– abnormal update rate
12
Red
111
Controller #1
Engine control module critical internal failure – bad
intelligent device or component
629
12
Amber
343
Controller #1
Engine control module warning internal hardware
failure – bad intelligent device or component
214053
444
Revision A
Summary of Contents for M1240
Page 29: ...SAFETY 1 11 Safety Sign Locations Figure 1 31 Safety Sign Locations 214053 17 Revision A ...
Page 40: ......
Page 116: ......
Page 246: ......
Page 352: ...MAINTENANCE AND SERVICING Figure 5 175 Main Fuse Panel Decal MD 207815 214053 340 Revision A ...
Page 370: ......
Page 388: ......
Page 487: ......