4.7 Operating with an A40-D Auger Header
The is factory-equipped to run an A40-D Auger Header.
For attachment instructions, refer to
Attaching an A40-D Auger Header, page 144
4.7.1 Adjusting Reel Speed
Reel speed is displayed in either rpm, mph, or km/h (depending on the global units selection). The default reel speed
is 60 rpm and can be set to auto or manual mode:
• MANUAL mode: Reel speed is set and is maintained regardless of ground speed. Refer to
• AUTO mode: Minimum reel speed and operating reel speed differential relative to ground speed are set, and reel
speed is maintained relative to ground speed. Refer to
Setting Reel Speed in Auto Mode, page 217
.
Setting Reel Speed in Auto Mode
This adjustment requires the header to be in operation.
1. If RUN SCREEN 1 is not already displayed, press soft
key 1 (A) on the Harvest Performance Tracker (HPT)
to display auger RUN SCREEN 1.
Figure 4.239: Header Run Screen 1
2. Press the scroll knob (A) on the Harvest Performance
Tracker (HPT) or the SELECT button (B) on the ground
speed lever (GSL) to display the QuickMenu system.
Figure 4.240: HPT Scroll Knob and GSL
Select Button
214053
217
Revision A
Summary of Contents for M1240