![MacDon M1240 Operator'S Manual Download Page 475](http://html.mh-extra.com/html/macdon/m1240/m1240_operators-manual_685727475.webp)
J1939
SPN
J1939
FMI
Lamp
Fault
Code
J1939 SPN Description
Cummins Description
3
Amber
4951
ECU power lamp
Maintain ECU power lamp – voltage above normal,
or shorted to high source
6655
4
Amber
4952
ECU power lamp
Maintain ECU power lamp – voltage below normal,
or shorted to low source
9
Amber
5177
VGT actuator driver
circuit
VGT actuator driver circuit – abnormal update rate
13
Red
4956
Variable geometry
turbocharger actuator
Variable geometry turbocharger actuator software
– out of calibration
6713
31
Red
4957
Variable geometry
turbocharger actuator
Variable geometry turbocharger actuator software
– condition exists
9
Amber
5653
SCR operator
inducement override
switch
SCR operator inducement override switch –
abnormal update rate
6881
13
Amber
5654
SCR operator
inducement override
switch
SCR operator inducement override switch – out of
calibration
3
Amber
5393
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – voltage above
normal or shorted to high source
4
Amber
5394
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – voltage below
normal or shorted to low source
9
Amber
5391
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – abnormal update
rate
11
Amber
5395
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – root cause not
known
12
Amber
5392
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – bad intelligent
device or component
6882
16
Amber
5396
Aftertreatment diesel
oxidation catalyst
temperature sensor
module
Aftertreatment diesel oxidation catalyst
temperature sensor module – data valid but above
normal operating range – moderately severe level
6918
31
Maintenance
5632
SCR system cleaning
inhibited due to inhibit
switch
SCR system cleaning inhibited due to inhibit switch
– condition exists
214053
463
Revision A
Summary of Contents for M1240
Page 29: ...SAFETY 1 11 Safety Sign Locations Figure 1 31 Safety Sign Locations 214053 17 Revision A ...
Page 40: ......
Page 116: ......
Page 246: ......
Page 352: ...MAINTENANCE AND SERVICING Figure 5 175 Main Fuse Panel Decal MD 207815 214053 340 Revision A ...
Page 370: ......
Page 388: ......
Page 487: ......