Address
Designation
Default setting
Data type
Factor A
M
Analog input 1: Minimum value for scaling
0.0 %
I16
10
-
Analog input 1: Maximum value for scaling
100.0 %
I16
10
-
Digital inputs internal control: Activation
Aus [0]
U8
X
Digital inputs internal control: DI1 internal control
Aus [0]
U8
X
Digital inputs internal control: DI2 internal control
Aus [0]
U8
X
Digital inputs internal control: DI3 internal control
Aus [0]
U8
X
Digital inputs internal control: DI4 internal control
Aus [0]
U8
X
Digital outputs internal control: Activation
Aus [0]
U8
X
Digital outputs internal control: DO1 internal control Aus [0]
U8
X
Analog inputs internal control: Activation
Aus [0]
U8
X
Analog inputs internal control: AI1 internal control
100.00 %
I16
100
X
Holding brake control: Brake mode
Off [2]
U8
-
●
Holding brake control: Brake closing time
100 ms
U16
1
-
Holding brake control: Brake opening time
100 ms
U16
1
-
Holding brake control: Brake detection
- (Read only)
U16
X
Holding brake control: Brake polarity
Normal [0]
U8
-
Holding brake control: Brake error response
Fault [1]
U8
-
Holding brake control: Starting torque source
Torque in 0x2820:010 [1]
U16
-
Holding brake control: Starting torque
0.0 %
I16
10
-
●
Holding brake control: Override of the brake control No override active [0]
U8
X
●
Holding brake control: Holding load ramptime
0 ms
U16
1
-
Holding brake control: Brake status
- (Read only)
U8
X
Holding brake control: Brake opening time test sig-
nal
500 ms
U16
1
X
Holding brake control: Brake control word
0x00
U8
HX
Holding brake control: Detected actual torque
x.x % (Read only)
I16
10
X
Holding brake control: Versorgungsspannung Halte-
bremse
Absenkung auf 75% [75]
U8
-
Axis commands: Enable inverter
Inverter enabled [1]
U8
X
0x2822:003
Axis commands: Reset error
Off/Ready [0]
U8
X
Axis commands: Load default Lh saturation charac-
teristic
Off/Ready [0]
U8
X
Axis commands: Load default inverter characteristic Off/Ready [0]
U8
X
Axis commands: Estimate optimum magnetizing cur-
rent
Off/Ready [0]
U8
X
Axis commands: Estimate motor parameter based
on rated data
Off/Ready [0]
U8
X
Axis commands: Get motor encoder characteristic
(resolver)
Off/Ready [0]
U8
X
Axis commands: Get motor encoder information
(Hiperface)
Off/Ready [0]
U8
X
Axis commands: Get load encoder/master encoder
characteristic (resolver)
Off / ready [0]
U8
X
Axis commands: Get load encoder/master encoder
information (Hiperface)
Off/Ready [0]
U8
X
0x2823
Status of axis commands
- (Read only)
U8
1
X
Control selection
Keypad [1]
U8
C
Drive mode selection
CiA402 operating modes [0]
U8
C
0x2826
Time-out for error response
4 s
U32
1
-
0x282A:001
Status words: Cause of disable
- (Read only)
U32
HX ●
0x282C:001
I/O diagnostic: Application level of the digital inputs - (Read only)
U32
HX ●
Inverter control word
0x0000
U16
HX ●
Inverter-Statuswort
- (Read only)
U16
HX ●
Motor identification status
- (Read only)
U16
HX
0x2833
Inverter status word 2
- (Read only)
U16
HX ●
* Default setting depending on the size.
Appendix
Parameter attribute list
468