Address
Name / setting range / [default setting]
Info
0x6060
Modes of operation
Selection of the operating mode.
0 No mode change/no mode assigned
No operating mode (standstill)
2 CiA: Velocity mode
CiA 402 velocity mode
Operating mode "CiA 402 Velocity mode (vl)"
8 Cyclic sync position mode
Operating mode "CiA 402 Cyclic sync position mode (csp)"
9 Cyclic sync velocity mode
Operating mode "CiA 402 Cyclic sync velocity mode (csv)"
10 Cyclic sync torque mode
Operating mode "CiA 402 Cyclic sync torque mode (cst)"
0x60B1
Velocity offset
-480000.00 ... [0.00] ... 480000.00 rpm
Additive value for setpoint velocity or velocity feedforward control.
0x60FF
Target velocity
-480000.00 ... [0.00] ... 480000.00 rpm
Setting of the setpoint velocity.
Configure speed control
Process input data (CiA 402 objects)
184