Parameter
Address
Name / setting range / [default setting]
Info
0x2878:004
Motor encoder: Encoder monitoring response time
•
Read only: ms
12 12 ms
50 50 ms
100 100 ms
0x287B:001
Velocity monitoring: Tolerance window (n=0)
•
Read only: x rpm
0x2894:001
SS1, SS2: SS1, SS2: Stopping time
•
Read only: x ms
0x2894:002
SS1, SS2: SS1, SS2: Ramp Monitoring
•
Read only
0 No Ramp monitoring
1 Ramp monitoring active
0x2894:003
SS1, SS2: SS1, SS2: Ramp smoothing time
•
Read only: x %
0x2894:004
SS1, SS2: SS1, SS2: Ramp Offset Mode
•
Read only
0 Relative
1 Absolute
0x2894:005
SS1, SS2: SS1, SS2: Ramp Start Offset relative
•
Read only: x %
0x2894:006
SS1, SS2: SS1, SS2: Ramp Start Offset absolute
•
Read only: x rpm
0x2894:007
SS1, SS2: SS1, SS2: Actual ramp speed
•
Read only: x rpm
0x2894:008
SS1, SS2: SS1, SS2: Minimal speed differerence
•
Read only: x rpm
0x2899
SS2: Source SD-In
•
Read only
0 Deactivated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x289A
SS2: Source S-Bus
•
Read only
0 Deactivated
1 Activated
0x289B:001
SS2: SS2: Mode
•
Read only
0 SOS after stop time
1 SOS at n=0
0x289C
SS2 active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
Safety functions
Safe Stop 2 (SS2)
408