Address
Designation
Default setting
Data type
Factor A
M
Field weakening controller settings: Reset time
(ASM)
2000.0 ms
U32
10
-
Field weakening controller Field limitation
100.00 %
U16
100
-
●
DC-bus filter time
25.0 ms
U16
10
-
Motor voltage filter time
25.0 ms
U16
10
-
Voltage reserve range
5 %
U8
1
-
V/f characteristic shape
Linear [0]
U8
C
V/f shape data: Base voltage
225 V
U16
1
-
V/f shape data: Base frequency
270 Hz
U16
1
-
Frequency grid points (x) user V/f characteristic: x1
= f01
-50 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x2
= f02
-40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x3
= f03
-30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x4
= f04
-20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x5
= f05
-10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x6
= f06
0 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x7
= f07
10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x8
= f08
20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x9
= f09
30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x10
= f10
40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x11
= f11
50 Hz
I16
1
-
Voltage grid points (y) user V/f characteristic: y1 =
U01 (x = f01)
400.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y2 =
U02 (x = f02)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y3 =
U03 (x = f03)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y4 =
U04 (x = f04)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y5 =
U05 (x = f05)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y6 =
U06 (x = f06)
0.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y7 =
U07 (x = f07)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y8 =
U08 (x = f08)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y9 =
U09 (x = f09)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y10 =
U10 (x = f10)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y11 =
U11 (x = f11)
400.00 V
U32
100
-
V/f boost controller - current setpoint
0.00 A
U32
100
-
V/f boost controller settings: Gain
148.21 V/A
U32
100
-
V/f boost controller settings: Reset time
3.77 ms
U32
100
-
Voltage boost
0.0 V
U16
10
-
Load adaption: Direction of rotation
Passive load [0]
U8
C
* Default setting depending on the size.
Appendix
Parameter attribute list
476