Behaviour of the function in the event of an error
If the maximum permissible position change is exceeded, an error stop is initiated. The follow-
ing functions can be set as safe stop:
When exceeding the position change in the OMS mode, the error stop set there
is used. See chapter "
Parameter
Address
Name / setting range / [default setting]
Info
0x28C8
SLI: Source SD-In
•
Read only
0 Deactivated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28C9
SLI: Source S-Bus
•
Read only
0 Deactivated
1 Activated
0x28CA:001
SLI: SLI: Increment size normal operation
•
Read only
0x28CA:002
SLI: SLI: Error reaction normal operation
•
Read only
0 STO
1 SS1
2 SS2
0x28CA:003
SLI: SLI: Increment size exceptional operation
•
Read only
0x28CA:004
SLI: SLI: Maximum change of Position
•
Read only
0x28CB
SLI active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
Safety functions
Safely Limited Increment (SLI)
419