Parameter
Address
Name / setting range / [default setting]
Info
0x2910:001
Inertia settings: Motor moment of inertia
0.00 ... [0.14] ... 20000000.00 kg cm²
Setting of the moment of inertia of the motor, relating to the motor.
0x2910:002
Inertia settings: Load moment of inertia
0.00 ... [0.00] ... 20000000.00 kg cm²
Setting of the moment of inertia of the load.
•
Always adjust the setting to the current load, otherwise the optimisa-
tion process for the speed controller cannot be executed successfully.
0x2910:003
Inertia settings: Coupling
Selection of the type of coupling between the moment of inertia of the
motor and that of the load.
0 Stiff
0x2910:004
Inertia settings: Mechanical natural frequency
0.0 ... [0.0] ... 250.0 Hz
Setting of the mechanical natural frequency.
0x2910:005
Inertia settings: Load moment of inertia (elastic cou-
pled)
0.00 ... [0.00] ... 20000000.00 kg cm²
Setting of the load moment of inertia with elastic coupling
(
For further details on the speed controller, see chapter "
".
Configuring the motor control
Options for optimising the control loops
Tuning of the motor and the speed controller
259