Address
Designation
Default setting
Data type
Factor A
M
Device: Ethernet commands: Device: Start firmware
update
Off/Ready [0]
U8
CX
Engineering port control
No action/No error [0]
U8
X
Engineering port settings: IP address
0.0.0.0
U32
E
Engineering port settings: Subnet
0.0.0.0
U32
E
Engineering port settings: Gateway
0.0.0.0
U32
E
Engineering port settings: DHCP
Enabled [1]
U8
-
Active engineering port settings: IP address
- (Read only)
U32
EX
Active engineering port settings: Subnet
- (Read only)
U32
EX
Active engineering port settings: Gateway
- (Read only)
U32
EX
Active engineering port settings: MAC address
- (Read only)
OCTET[6]
X
NTP server addresses: Activate NTP server
addresses
No action/no error [0]
U8
X
NTP server addresses: NTP server address 1
0.0.0.0
U32
E
NTP server addresses: NTP server address 2
0.0.0.0
U32
E
NTP server addresses: NTP server address 3
0.0.0.0
U32
E
NTP server addresses: NTP server address 4
0.0.0.0
U32
E
System time: Time base
NTP [0]
U8
X
System time: Current time
ns
U64
1
TX
Touch probe filter time
0 us
U16
1
-
0x2539:001
Hardware-Diagnose: 24 V supply actual voltage
x.x V (Read only)
U16
10
X
0x2539:002
Hardware-Diagnose: Control board temperature
x.x °C (Read only)
I16
10
X
Mains settings: Rated mains voltage
400 Veff [1]
U8
-
Mains settings: Undervoltage warning threshold
430 V
U16
1
-
Mains settings: Undervoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Undervoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage warning threshold
795 V
U16
1
-
Mains settings: Overvoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: DC link voltage critical
- (Read only)
U8
1
X
●
Brake energy management: Reduced threshold
0 V
U16
1
-
Brake resistor: Minimum resistance
x.x Ω (Read only)
U16
10
X
Brake resistor: Resistance value
180.0 Ω
U16
10
-
Brake resistor: Rated power
5600 W
U32
1
-
Brake resistor: Maximum thermal load
485 kWs
U32
1
-
Brake resistor: Reference resistance
Minimum resistance [0]
U8
-
Brake resistor: Thermal load
x.x % (Read only)
U16
10
X
Brake resistor: Warning threshold
90.0 %
U16
10
-
Brake resistor: Response to warning
Warning [2]
U8
-
Brake resistor: Response to error
No response [0]
U8
-
Distributed Clocks : Real time status
- (Read only)
U8
X
Distributed Clocks : First setting time
x ns (Read only)
U64
1
TX
Distributed Clocks : Newest setting time
x ns (Read only)
U64
1
TX
Distributed Clocks : Current time
x ns (Read only)
U64
1
TX
Energy saving: State of actual energy saving mode
- (Read only)
U8
HX
Favorites settings: Parameter 1
U32
1
-
Favorites settings: Parameter 2
U32
1
-
Favorites settings: Parameter 3
U32
1
-
Favorites settings: Parameter 4
U32
1
-
Favorites settings: Parameter 5
U32
1
-
Favorites settings: Parameter 6
U32
1
-
Favorites settings: Parameter 7
U32
1
-
Favorites settings: Parameter 8
U32
1
-
Favorites settings: Parameter 9
U32
1
-
* Default setting depending on the size.
Appendix
Parameter attribute list