6.4.2.2
Source of touch probe time stamp
The Touch probe system bus source parameter serves to set the source of the touch probe
time stamp.
Time stamp TP (0x5021:165)
System bus outputs
Source TP 1
(0x5020:011)
Time stamp TP: System bus in
(0x5021:155)
DigIn1 - Positive edge
DigIn4 - Negative edge
DigIn4 - Any edge
••
••
•
Fig. 25: Selection of the source of the touch probe time stamp
Parameter
Address
Name / setting range / [default setting]
Info
0x5020:011
TP1 source
The sensor source and the edge to be evaluated are selected via the
parameter (rising, falling, any)
0 External source
Source: System bus
1 Digital input 1, positive edge
2 Digital input 1, negative edge
3 Digital input 1, any edge
11 Digital input 2, positive edge
12 Digital input 2, negative edge
13 Digital input 2, any edge
21 Digital input 3, positive edge
22 Digital input 3, negative edge
23 Digital input 3, any edge
31 Digital input 4, positive edge
32 Digital input 4, negative edge
33 Digital input 4, any edge
0x5020:012
TP2 source
0 External source
1 Digital input 1, positive edge
2 Digital input 1, negative edge
3 Digital input 1, any edge
11 Digital input 2, positive edge
12 Digital input 2, negative edge
13 Digital input 2, any edge
21 Digital input 3, positive edge
22 Digital input 3, negative edge
23 Digital input 3, any edge
31 Digital input 4, positive edge
32 Digital input 4, negative edge
33 Digital input 4, any edge
0x5021:155
System bus diagnostics: Time stamp (input value)
•
Read only: x ns
Time stamp of the master axis
0x5021:165
System bus diagnostics: Time stamp (output value)
•
Read only: x ns
Time stamp of the touchprobe source in ns selected via source TP1
.