Address
Name / setting range / [default setting]
Info
0x5021:166
System bus diagnostics: Output data word 6
•
Read only
This system bus input word is currently not used, but can be connected
in the technology application by the user.
0x5021:167
System bus diagnostics: Output data word 7
•
Read only
6.4.2.1
Master value output
The system bus is used to distribute process data in a connection.
A technology application can provide its own setpoint values and actual values or the setpoint
values and actual values of an optional encoder connected via the slot (B) for other technol-
ogy applications. The values are transferred independently of the role of the node in the sys-
tem bus (master or slave). The values are configured via the Master value output of system
bus parameter. Every bus node sends the values.
Cycle length (0x5021:160)
Position (0x5021:161)
Velocity (0x5021:162)
Acceleration (0x5021:163)
Torque (0x5021:164)
System bus outputs
Master values output system bus
(0x5020:001)
None: 0
Own axis det values: 1
Own axis act values: 2
Application feedback (B): 3
Virtual master: 4
Fig. 24: Selection of the source for the master value output
"Virtual Master: 4" can be selected in the following technology applications:
•
Electronic Gearbox
•
Sync and correction
•
Cross cutter
Technology application (TA) basic settings