6.2.10.2
Digital input for reference switch
Parameter
Address
Name / setting range / [default setting]
Info
0x5020:006
Source of homing switch for touch probe
Selection of the signal source for activating the reference switch for
touch probe evaluation.
0 FALSE
1 TRUE
2 Digital input 1
3 Digital input 2
4 Digital input 3
5 Digital input 4
6.2.10.3
Motor/encoder behaviour after mains switching
With multipole resolvers, a renewed referencing is required.
The home position is deleted when:
•
The home position is not within the parameterised angle after switching on.
•
The encoder shaft is rotated by ≥ 50% when using resolvers.
•
The encoder shaft is rotated by ≥ 50% when using single turn absolute value encoders.
Conditions for obtaining the home position after mains switching:
•
Set parameter to 1:Active.
•
Observe maximum configurable angle of rotation. Parameterise ≤ 50% of maximum pre-
sentable range of encoder shaft.
No check takes place when:
•
The angle is parameterised for 0°.
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:081
Keep home position after mains switching
false Inactive
true Active
0x500A:082
Max. angle of rotation after mains switching
-2147483648.0000000000 ... [0.0000000000] ...
2147483647.0000000000 °
Setting of the maximum angle of rotation for the motor.
•
The angle of rotation must be parameterised smaller than half of the
maximum display area des Gebers.
•
If the angle is parameterised to 0°, no check will be performed.
0x500B:081
Keep home position after mains switching
false Inactive
true Active
0x500B:082
Max. angle of rotation after mains switching
-2147483648.0000000000 ... [0.0000000000] ...
2147483647.0000000000 °
Setting of the maximum angle of rotation for the encoder.
•
The angle of rotation must be parameterised smaller than 50% of the
maximum display area of the encoder.
•
If the angle is parameterised to 0°, there will be no check.