Address
Name / setting range / [default setting]
Info
0x28C4:004
SLS: Permitted direction: SLS4: Permitted direction
•
Read only
0 Both directions enabled
1 Positive direction enabled
2 Negative direction enabled
0x28C5:001
SLS: Reaction (n>Nlim): SLS1: Reaction (n>Nlim1)
•
Read only
0 STO
1 SS1
2 SS2
0x28C5:002
SLS: Reaction (n>Nlim): SLS2: Reaction (n>Nlim2)
•
Read only
0 STO
1 SS1
2 SS2
0x28C5:003
SLS: Reaction (n>Nlim): SLS3: Reaction (n>Nlim3)
•
Read only
0 STO
1 SS1
2 SS2
0x28C5:004
SLS: Reaction (n>Nlim): SLS4: Reaction (n>Nlim4)
•
Read only
0 STO
1 SS1
2 SS2
0x28C6:001
SLS active: Output: SLS1 active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28C6:002
SLS active: Output: SLS2 active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28C6:003
SLS active: Output: SLS3 active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28C6:004
SLS active: Output: SLS4 active: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28C7:001
SLS Monitored: Output: SLS1 Monitored: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28C7:002
SLS Monitored: Output: SLS2 Monitored: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
Safety functions
Safely-Limited Speed (SLS)
415