Master-Position [u]
eSyncMode = Ramp_VelAcc
profile parameters
xSyncPos
xAccDecSync
xSynchronised
Master-Position [u]
Slave-Position [u]
IrSyncVel, IrSynAcc, IrSyncDec, IrSyncJerk
IrSlaveSyncOutPos
Fig. 56: Coupling disengages with eSyncMode = 4 Ramp_Time
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
Declutch position
0.0000
0.0000 ... 214748.3647
Clutch jerk
10000.0000
0.0000 ... 214748.3647
Configuring the "Sync and Correction" TA
Position clutch
Travel profile-based clutch
132