Toolbar
Icon
Function
Load oscillogram / configuration from file
Load recorded oscillogram from the device
Save oscillogram in file
Copy oscillogram to the clipboard
Print oscillogram
Display cursor
Centre cursor
Scale curve automatically
Activate zoom function
"Time base:"
Display of the set time base
Tool settings (right-hand side of the toolbar)
Technical data
Number of channels
1 ... 8
Data memory depth
Maximally 2048 measured values for each channel
Data width of a channel Maximally 64 bits, according to the data type of the parameter to be recorded
Sample rate
62.5 µs or a multiple thereof
Minimum recording time 128 ms
(62.5 µs * 2048 measured values)
Maximum time base
20.47 s
Maximum recording
time
20.47 s
Trigger level
According to the value range of the parameter to be triggered
Trigger selection
Trigger delay
-100 % ... +400 %
Trigger source
Channel 1 ... 8
Additional functions
Oscilloscope function
389