Diagnostics
Status word parameter bit 9
Status word parameter bit 10
Bit 10
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:104
Response to hardware limit switch error
19 Fault > Application quick stop > Quick stop
21 Fault> Application quick stop > Inverter disa-
bled
0x5020:004
Source of positive hardware limit switch
Selection of the digital inputs for the positive hardware limit switch.
0 FALSE
Specification of the digital inputs for the positive hardware limit switch.
1 TRUE
2 Digital input 1
3 Digital input 2
4 Digital input 3
5 Digital input 4
0x5020:005
Source of negative hardware limit switch
Selection of the digital inputs for the negative hardware limit switch.
0 FALSE
Specification of the digital inputs for the negative hardware limit switch.
1 TRUE
2 Digital input 1
3 Digital input 2
4 Digital input 3
5 Digital input 4
Technology application (TA) basic settings
Motion settings
Limitations