Parameter
Address
Name / setting range / [default setting]
Info
0x2D4D:001
Motor utilisation (i²xt) - specific characteristic: x1 =
n01/nN (n01 ~ 0)
0 ... [0] ... 600 %
User-definable characteristic for speed-dependent evaluation of the
motor current.
0x2D4D:002
Motor utilisation (i²xt) - specific characteristic: y1 =
i01/iN (x1)
0 ... [100] ... 600 %
0x2D4D:003
Motor utilisation (i²xt) - specific characteristic: x2 =
n02/nN (n02 = limit reduced cooling)
0 ... [0] ... 600 %
0x2D4D:004
Motor utilisation (i²xt) - specific characteristic: y2 =
i02/iN (x2)
0 ... [100] ... 600 %
0x2D4D:005
Motor utilisation (i²xt) - specific characteristic: x3 =
n03/nN (n03 = rated speed)
0 ... [100] ... 600 %
0x2D4D:006
Motor utilisation (i²xt) - specific characteristic: y3 =
i03/iN (x3)
0 ... [100] ... 600 %
0x2D4D:007
Motor utilisation (i²xt) - specific characteristic: x4 =
n04/nN (n04 = limit field weakening)
0 ... [100] ... 600 %
0x2D4D:008
Motor utilisation (i²xt) - specific characteristic: y4 =
i04/iN (x4)
0 ... [100] ... 600 %
Configuring the motor control
Motor protection
Motor overload monitoring (i²*t)
294