Address
Designation
Default setting
Data type
Factor A
M
Load encoder: Load encoder gearbox factor numer-
ator
- (Read only)
U16
1
-
Load encoder: Load encoder gearbox factor denomi-
nator
- (Read only)
U16
1
-
Load encoder: Load encoder mounting direction
- (Read only)
U8
-
Load encoder: Load encoder position
0
I32
1
X
●
Load encoder: Status of load encoder position
Invalid [0]
U8
X
●
Velocity monitoring: Tolerance window (n=0)
x rpm (Read only)
U16
1
-
Velocity monitoring: Velocity comparison tolerance x rpm (Read only)
U16
1
-
Velocity monitoring: Actual velocity n_safe
x rpm (Read only)
I16
1
X
●
Velocity monitoring: Internal actual velocity nSD
x rpm (Read only)
I16
1
X
Velocity monitoring: Internal actual velocity nBD
x rpm (Read only)
I16
1
X
Velocity monitoring: Actual velocity difference nSD-
nBD
x rpm (Read only)
I16
1
X
Position monitoring: Position comparison tolerance - (Read only)
I32
1
-
Position monitoring: Actual Position p_safe
- (Read only)
I32
1
X
●
Position monitoring: Internal actual position pSD
- (Read only)
I32
1
X
Position monitoring: Internal actual position pBD
- (Read only)
I32
1
X
Position monitoring: Current pos. difference pSD-
pBD
- (Read only)
I32
1
X
SHOM_Start settings: SHOM_Start: Source
- (Read only)
U8
-
SHOM_Start settings: SHOM_Start: Edge trigger IRS - (Read only)
U8
-
SHOM_Load settings: SHOM_Load: Source
- (Read only)
U8
-
SHOM_Load settings: SHOM_Load: Edge trigger IRL - (Read only)
U8
-
Safe homing (SHOM): SHOM: Home position
- (Read only)
I32
1
-
Safe homing (SHOM): SHOM: Timeout
x ms (Read only)
U16
1
-
Safe homing (SHOM): SHOM: SLS homing
- (Read only)
U8
-
Safe homing (SHOM): SHOM: Restart condition
- (Read only)
U8
-
Safe homing (SHOM): SHOM: Tolerance - starting
position
- (Read only)
I32
1
-
Safe homing (SHOM): SHOM status
- (Read only)
U8
X
Safe homing (SHOM): SHOM: Saved position
- (Read only)
I32
1
X
SHOM: Diagnostic positions source
- (Read only)
U8
-
SHOM diagnostic positions: SHOM: Detection diag
position
- (Read only)
U8
-
SHOM diagnostic positions: SHOM: Lower diagnostic
position
- (Read only)
I32
1
-
SHOM diagnostic positions: SHOM: Upper diagnos-
tic position
- (Read only)
I32
1
-
SHOM diagnostic positions: SHOM: Tolerance diag
positions
- (Read only)
I32
1
-
SHOM diagnostic positions: SHOM: Error response
diag positions
- (Read only)
U8
-
SHOM diagnostic positions: SHOM: Current differ-
ence diagnostic position
- (Read only)
I32
1
X
SHOM: Slip compensation: SHOM: Maximally com-
pensated slip
- (Read only)
I32
1
-
SHOM: Slip compensation: SHOM: Slip compensa-
tion end area
- (Read only)
U8
-
SHOM: SHOM active output
- (Read only)
U8
-
SHOM: SHOM available output
- (Read only)
U8
-
STO: Source SD-In
- (Read only)
U8
-
STO: Source S-Bus
- (Read only)
U8
-
STO: STO: Restart
- (Read only)
U8
-
STO active: Output
- (Read only)
U8
-
SS1, SS2: SS1, SS2: Stopping time
x ms (Read only)
U16
1
-