6.4.3.3
Example: Using time stamp of another axis
The touch probe timestamp of the technology application Sync and correction (S1) is to be
used by the technology application Table Positioning (S2). The master value master is the vir-
tual master in the system bus master.
M (VM)
S1
S2
TP
Fig. 29: Example 3 - Using the timestamp of another axis
M = System bus master
VM = Virtual master
S = Slave
TP = Touch probe
In order to allow the timestamp of Slave 1 to be used by Slave 2 as well, the Parameter source
for word 5 (Slave 2) parameter must be set to Slave 1 [2] (see following table). 0x5021:042
System bus
Input words
Master
Slave 1
Slave 2
. . .
Slave 15
00
Taktlänge der Lei-
tachse
(0x5021:150)
0x5021: 010
01: Master
. . .
0x5021:010
01: Master
01
Positionsleitwert
(0x5021:151)
02
Geschwindigkeitsleit-
wert
(0x5021:152)
03
Beschleunigungsleit-
wert
(0x5021:153)
04
Drehmoment der Lei-
tachse
(0x5021:154)
0x5021:020
01: Master
0x5021:021
01: Master
0x5021:022
01: Master
0x5021:035
01: Master
05
Zeitstempel der Lei-
tachse
(0x5021:155)
0x5021:040
01: Master
0x5021:041
01: Master
0x5021:042
02: Slave 1
0x5021:055
01: Master
06
Free input word
(0x5021:156)
0x5021:060
01: Master
0x5021:061
01: Master
0x5021:062
01: Master
0x5021:075
01: Master
07
Free input word
(0x5021:157)
0x5021:080
01: Master
0x5021:081
01: Master
0x5021:082
01: Master
0x5021:095
01: Master
As shown in the table, the parameters 0x5021:020 ... 095 can also be used for the distribution
of the torque values and for specific data from the technology application.
Technology application (TA) basic settings
System bus communication
Distribution of the master values by the master