Saving oscillogram in file
The reuse of a saved configuration is only reasonable for inverters of the same
type (e. g. i950 inverters), as otherwise due to a scaling of the oscilloscope chan-
nels that is not adapted, incorrect values are displayed!
After selecting the parameters to be recorded from the selection list of the signal sources and
making any further necessary settings, you can save this configuration and the recording if
already carried out on the Engineering PC for a later reuse.
How to save the oscillogram:
1. Click the symbol in the toolbar. the "Save oscillogram" dialog box is displayed.
2. Define a name in the Name input field of the oscillogram to be saved.
3. Click the "Export to file" button.
4. Specify the folder and file name for the oscillogram be stored in the Save as dialog box.
5. Click the Save button. The dialog box is closed.
The current oscillogram is saved.
Loading oscillogram / configuration from file
The reuse of a saved configuration is only reasonable for inverters of the same
type (e.g. i950 inverters), as otherwise due to a scaling of the oscilloscope chan-
nels that is not adapted, incorrect values are displayed!
Data sets/configurations which have already been saved can be reloaded into the oscilloscope
any time, e.g. for the overlay function.
How to load an oscillogram or a configuration:
1. Click the symbol in the oscilloscope toolbar. The "Load oscillogram" dialog box is displayed.
2. Press the Search... button.
3. Select the file to be imported within the desktop environment from the Open dialog box.
4. If the oscillogram is to be used as configuration, select the As configuration... option.
5. Click the Open button. The dialog box is closed.
The selected oscillogram or configuration is imported.
Closing the oscillogram
You can close an open OFFLINE oscillogram again any time.
•
After an oscillogram is closed, it is no longer available in the oscillogram list field. The oscil-
loscope changes automatically to the display of the ONLINE oscillogram.
•
If the closed oscillogram was included in the MERGE oscillogram, its channels will be
removed from the MERGE oscillogram.
•
Go to the oscilloscope toolbar and click the symbol to close the currently displayed OFF-
LINE oscillogram.
Overlay function
The overlay function serves to overlay several characteristics from the currently loaded data
sets, e.g. to compare signal characteristics from different recordings.
•
If two or more oscillograms are loaded in the oscilloscope, e.g. the ONLINE oscillogram and
an oscillogram that was previously loaded into a file, a "MERGE" oscillogram will be auto-
matically available in the "Oscillogram" list field.
•
If the merge oscillogram is selected, the desired characteristics to be overlaid or compared
can be selected from the loaded oscillograms in the Vertical channel settings group field.
•
If an ONLINE oscillogram is used in the MERGE oscillogram, an update is carried out in the
MERGE oscillogram in the case of a renewed recording.
•
Removing variables from an OFFLINE or ONLINE oscillogram causes the characteristics in
the MERGE oscillogram to be deleted.