16.1.5.2
Enable operation
This command enables the operation and stop an active quick stop again.
•
A changeover to the "
" device status takes place.
•
The output stages of the inverter become active.
A
From all states
B
Power section inhibited (pulse inhibit)
C
Power section enabled
Bit pattern in the CiA 402 control word (
Bit 15 ... 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
(specific)
Reset fault
Operating mode dependent
Operation
enabled
Activating
quick stop
Establish read-
iness for oper-
ation
Switch-on
X
0
X
X
X
1
1
1
1
X = state is not relevant
Configuring the network
Device profile CiA 402
Commands for device state control
320