Parameter
Address
Name / setting range / [default setting]
Info
0x5040:001
Simulation of control signals
0x00 ... [0x00] ... 0xFF
Bit 0 Enable control signal simulation
TRUE: Simulation of the control signals is activated.
FALSE: The control signals are transmitted via the active network inter-
face.
Bit 1 Activate simulation of control word 1
TRUE: Simulation of control word 1 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 2 Activate simulation of control word 2
TRUE: Simulation of control word 2 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 3 Activate simulation of control word 3
TRUE: Simulation of control word 3 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 4 Activate simulation of control word 4
TRUE: Simulation of control word 4 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 5 Activate simulation of control word 5
TRUE: Simulation of control word 5 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 6 Activate simulation of control word 6
TRUE: Simulation of control word 6 is activated.
FALSE: The control word is transmitted via the active network interface.
Bit 7 Activate simulation of control word 7
0x5040:101
Simulation of status signals
0x00 ... [0x00] ... 0xFF
Bit 0
Configuring the "Sync and Correction" TA
Interface
Simulation of the interface
96