10.2
Operating mode "CiA 402 Velocity mode (vl)"
Selection of the operating mode
The "speed" operating mode is selected with the setting "2" in
.
10.2.1
Default mapping
The default mapping for the "Speed" operating mode is defined in the following parameters.
Parameter
Designation
Data type
0x1603
RPDO-->axis: Velocity mode (vl)
RECORD
0x1A03
Axis-->TPDO: Velocity mode (vl)
RECORD
Data received from the Controller (RPDO)
Parameter
Designation
Data type
0x6040
CiA402 control word
UNSIGNED_16
0x2830
Lenze control word
UNSIGNED_16
0x6060
Operating mode: selection
INTEGER_8
0x6042
Velocity: setpoint velocity vl
INTEGER_8
Data sent to the Controller (TPDO)
Parameter
Designation
Data type
0x6041
CiA402 control word
UNSIGNED_16
0x2831
Lenze control word
UNSIGNED_16
0x6061
Operating mode: display
INTEGER_8
0x603F
Error code
UNSIGNED_16
0x6044
Velocity: actual velocity vl
INTEGER_8
Configure speed control
Operating mode "CiA 402 Velocity mode (vl)"
Default mapping
172