trained service technician.
Error code
Description
Action
201-000-xxx
Passed the memory stress test.
202-000-xxx
Passed the memory stress test.
202-801-xxx
Failed the memory stress test due to an
internal program error.
1. Turn off and restart the blade server. See
“Turning off the blade server” on page 12 and
“Turning on the blade server” on page 11.
2. Make sure that the DSA code is up-to-date;
upgrade if necessary. The latest code can be
found at http://www.ibm.com/systems/ support/
supportsite.wss/docdisplay? brandind=
5000008&lndocid=SERV-DSA.
3. Make sure that the system UEFI firmware is at
the latest level; upgrade if necessary. The
firmware level can be found in the DSA log
within the Firmware/VPD section for this
component. The latest level firmware for this
component can be found at http://www.ibm.
com/support/ fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
4. Run the test again.
5. Turn off and restart the blade server, if
necessary, if the blade server hangs. See
“Turning off the blade server” on page 12 and
“Turning on the blade server” on page 11
6. Run the standard DSA memory diagnostic tests
to identify the failing DIMM.
7. Reseat the DIMMs. See “Removing a DIMM -
BladeCenter HX5” on page 103 and “Installing a
DIMM - BladeCenter HX5” on page 104.
8. Run the test again.
9. See “Removing a DIMM - BladeCenter HX5” on
page 103 and “Installing a DIMM - BladeCenter
HX5” on page 104 to replace the failing DIMMs.
217
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...