• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
3048006
Booted secondary (backup)
UEFI image because of
automatic boot failure
recovery
1. Run the Setup utility (see “Using the Setup utility” on page 20).
Select
Load Default Settings
and save the settings to recover the
server firmware.
2. Remove the blade server from the chassis.
3. Install the blade server into the chassis and turn on the blade server.
305000A
Real time clock (RTC) date/
time is incorrect
1. Run the Setup utility (see “Using the Setup utility” on page 20) to
adjust the date and time. Then, restart the blade server.
2. Reseat the battery.
3. Replace the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. (Trained service technician only) System board (see “Removing
the system-board assembly - BladeCenter HX5” on page 140
and “Installing the system-board assembly - BladeCenter HX5”
on page 142).
3058001
System configuration is not
valid
1. Run the Setup utility (see “Using the Setup utility” on page 20).
Select
Load Default Settings
and save the settings.
2. Reseat the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. Failing device. If the device is a field replaceable unit (FRU), it
must be replaced by a trained service technician.
3. Replace the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. Failing device. If the device is a field replaceable unit (FRU), it
must be replaced by a trained service technician.
c. (Trained service technician only) System board (see “Removing
the system-board assembly - BladeCenter HX5” on page 140
and “Installing the system-board assembly - BladeCenter HX5”
on page 142)
3058004
Three boot failures
1. Undo any recent system changes, such as new settings or newly
installed devices.
2. Check the advanced management module event log for any power
related issues and resolve them. You can access the event log
through the advanced management module web interface. For more
information see the
Advanced Management Module Installation and
User's Guide
.
3. Remove all hardware that is not listed on the ServerProven website.
4. Run the Setup utility (see “Using the Setup utility” on page 20).
Select
Load Default Settings
and save the settings. Then, restart
the blade server.
159
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...