• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Error
Group 1, memory (One of the
DIMMs) memory configuration error
Make sure that the DIMMs are installed in the correct order
and configured correctly (see “Installing a DIMM - BladeCenter
HX5” on page 104).
If you receive this error code for a blade server configuration
that includes an IBM MAX5 expansion blade, multiple DIMMs
might have been disabled. After you replace the mismatched
DIMM, make sure that all DIMMs have been enabled using the
Setup utility (see “Using the Setup utility” on page 20) or using
the Advanced Settings Utility (see “Using the Advanced
Settings Utility (ASU)” on page 25).
Error
Memory device
X
(DIMM
X
Status)
memory configuration error [Note
X
=
1-16]
Make sure that the DIMMs are installed in the correct order
and configured correctly (see “Installing a DIMM - BladeCenter
HX5” on page 104).
If you receive this error code for a blade server configuration
that includes an IBM MAX5 expansion blade, multiple DIMMs
might have been disabled. After you replace the mismatched
DIMM, make sure that all DIMMs have been enabled using the
Setup utility (see “Using the Setup utility” on page 20) or using
the Advanced Settings Utility (see “Using the Advanced
Settings Utility (ASU)” on page 25).
Error
Memory device
X
(MEU DIMM
X
Status) memory configuration error
[Note
X
=1-24]
Make sure that the DIMMs are installed in the correct order
and configured correctly (see “Installing a DIMM - IBM MAX5”
on page 108).
If you receive this error code for a blade server configuration
that includes an IBM MAX5 expansion blade, multiple DIMMs
might have been disabled. After you replace the mismatched
DIMM, make sure that all DIMMs have been enabled using the
Setup utility (see “Using the Setup utility” on page 20) or using
the Advanced Settings Utility (see “Using the Advanced
Settings Utility (ASU)” on page 25).
Error Code: 0x806F070D
Note:
Multiple events can be displayed for this error code. Be sure to read the message text to determine the
appropriate recovery actions.
Information
Hard drive
X
(SSD Exp Drive
X
)
rebuild in progress
Information only; no action is required.
Information
Hard drive
X
(SSD Exp Drive
X
)
rebuild complete
Information only; no action is required.
Error Code: 0x806F0807
Note:
Multiple events can be displayed for this error code. Be sure to read the message text to determine the
appropriate recovery actions.
199
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...