• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Error
Group 4, processor (One of CPUs)
configuration error
1. (Trained service personnel only) Remove the blade server
and reseat the processors (see “Removing a
microprocessor and heat sink” on page 130 and “Installing
a microprocessor and heat sink” on page 134).
2. Verify that the system is running the latest UEFI firmware
(see “Updating firmware and device drivers” on page 30).
3. Run the Setup utility (see “Using the Setup utility” on page
a. Make sure that both processors are displayed by the
system.
b. Load the default settings.
c. Go to the
System Settings
menu and make sure the
processor is enabled.
Error
Group 4, processor (4S CPU)
configuration error
1. (Trained service personnel only) Remove the blade server
and reseat the processors (see “Removing a
microprocessor and heat sink” on page 130 and “Installing
a microprocessor and heat sink” on page 134).
2. Verify that the system is running the latest UEFI firmware
(see “Updating firmware and device drivers” on page 30).
3. Run the Setup utility (see “Using the Setup utility” on page
a. Make sure that both processors are displayed by the
system.
b. Load the default settings.
c. Go to the
System Settings
menu and make sure the
processor is enabled.
Error
Group 4, processor (2S CPU)
configuration error
1. (Trained service personnel only) Remove the blade server
and reseat the processors (see “Removing a
microprocessor and heat sink” on page 130 and “Installing
a microprocessor and heat sink” on page 134).
2. Verify that the system is running the latest UEFI firmware
(see “Updating firmware and device drivers” on page 30).
3. Run the Setup utility (see “Using the Setup utility” on page
a. Make sure that both processors are displayed by the
system.
b. Load the default settings.
c. Go to the
System Settings
menu and make sure the
processor is enabled.
194
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...