• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
089-000-xxx
Passed the CPU stress test
N/A
089-801-xxx
Aborted due to an internal program error.
1. If the blade server has stopped responding, turn
off and restart the blade server. See “Turning off
the blade server” on page 12 and “Turning on
the blade server” on page 11.
2. Make sure that the DSA code is up-to-date,
upgrade if necessary; then, run the test again.
The latest code can be found at http://www.ibm.
com/systems/ support/supportsite.wss/
docdisplay? brandind=5000008&lndocid=
SERV-DSA.
3. Make sure that the system firmware level is up-
to-date, upgrade if necessary; then, run the test
again. The installed firmware level can be found
in the DSA log within the Firmware/VPD section
for this component. The latest level firmware for
this component can be found at http://www.
ibm.com/support/ fixcentral/systemx/
groupView? query.productGroup=ibm%
2FBladeCenter.
4. If the blade server has stopped responding, turn
off and restart the blade server; then, run the
test again. See “Turning off the blade server” on
page 12 and “Turning on the blade server” on
page 11.
5. (Trained service technician only) If the
component failure remains, see Chapter 4
“Removing and replacing blade server
components” on page 65 to replace the failed
component.
214
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...