Microprocessor
retainer
Microprocessor
release lever
a. Rotate the release lever on the microprocessor socket from its closed and locked position until
it stops in the fully open position (approximately a 135° angle).
b. Rotate the microprocessor retainer on the microprocessor socket from its closed position until
it stops in the fully open position (approximately a 135° angle).
Step 10. If a dust cover is installed over the microprocessor socket, lift the dust cover from the socket and
store it in a safe place.
Step 11. Install the microprocessor in the microprocessor installation tool.
Attention:
If you are installing E7 series microprocessors in the blade server, you must use the
microprocessor installation tool with the text “X7500 + E7” on the bottom of the tool (see the
following illustration). Tools that do not have this text on the bottom will not work correctly with the
E7 series microprocessors.
X7500
+
E7
a. Remove the static-protective bag and the foam surrounding the bag from the box.
b. Touch the static-protective bag that contains the new microprocessor to any
unpainted
surface on the BladeCenter chassis or any
unpainted
metal surface on any other grounded
rack component.
c. Carefully remove the microprocessor from the static-protective bag, touching only the edges
of the microprocessor.
d. If there is a plastic protective cover on the bottom of the microprocessor, carefully remove it.
136
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...