• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Warning
System board, Power Module
(EPOW Fault) predictive failure
This warning message generally indicates that power
redundancy for the blade was lost. The non redundant
condition may have subsequently transitioned back to
redundant power state.
1. Check to see if a power module has been removed or
replaced and ensure the power modules are installed and
functioning properly (see the I
nstallation and User's Guide
for your chassis).
2. If this warning message is not a result of power
redundancy state changes, and there are no other
indications of chassis power issues, (trained service
technician only) replace the system board assembly (see
“Removing an IBM MAX5 expansion blade” on page 87
and “Installing an IBM MAX5 expansion blade” on page
88).
Error Code: 0x806F020D
Warning
Hard drive
X
(SSD Exp Drive
X
)
predictive failure [Note:
X
=1,2]
Replace the storage drive (see “Removing a solid state drive”
on page 101 and “Installing a solid state drive” on page 102).
Error Code: 0x806F0229
Information
PCI express bus 3, battery (SAS DC
Batt) absent.
Information only; no action is required.
Error Code: 0x806F030C
Error
Memory device
X
(DIMM
X
Status)
memory scrub failed [Note:
X
=1-16]
1. Refer to TIP H21455 for minimum code level.
2. Check the IBM support website for an applicable retain tip
or firmware update that applies to this memory error.
3. Swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different
memory channel or microprocessor (see “Installing a
DIMM - BladeCenter HX5” on page 104 for memory
population sequence).
4. Enable all affected DIMMs using the Setup utility.
5. If the failure remains on the original DIMM slots, replace
the DIMM that was not moved. If the failure follows the
DIMM that was moved, replace the DIMM that was
swapped.
6. If the problem occurs on the same DIMM connector,
check the DIMM connector. If the connector is damaged,
(Trained service technician only) replace the system-board
assembly (see “Removing the system-board assembly -
BladeCenter HX5” on page 140 and “Installing the
system-board assembly - BladeCenter HX5” on page
142).
Error Code: 0x806F0313
191
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...