• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
3818005
Current Bank Core Root of
Trust Measurement (CRTM)
capsule signature invalid
1. Revert to a previous version of the firmware for the blade server.
2. If the blade server will not start, switch to the backup UEFI image.
Set switch 7 to the on position. See “System-board switches” on
page 13 for the location of switch 7.
3. Update the firmware for the server. Make sure that you are using the
latest firmware from http://www.ibm.com/support/ fixcentral/
systemx/groupView? query.productGroup=ibm%2FBladeCenter.
4. Set switch 7 to the off position. See “System-board switches” on
page 13 for the location of switch 7.
3818006
Opposite bank CRTM
capsule signature invalid
1. Revert to a previous version of the firmware for the blade server.
2. If the blade server will not start, switch to the backup UEFI image.
Set switch 7 to the on position. See “System-board switches” on
page 13 for the location of switch 7.
3. Update the firmware for the server. Make sure that you are using the
latest firmware from http://www.ibm.com/support/ fixcentral/
systemx/groupView? query.productGroup=ibm%2FBladeCenter.
4. Set switch 7 to the off position. See “System-board switches” on
page 13 for the location of switch 7.
3818007
CRTM update capsule
signature invalid
1. Revert to a previous version of the firmware for the blade server.
2. If the blade server will not start, switch to the backup UEFI image.
Set switch 7 to the on position. See “System-board switches” on
page 13 for the location of switch 7.
3. Update the firmware for the server. Make sure that you are using the
latest firmware from http://www.ibm.com/support/ fixcentral/
systemx/groupView? query.productGroup=ibm%2FBladeCenter.
4. Set switch 7 to the off position. See “System-board switches” on
page 13 for the location of switch 7.
3828004
AEM power capping
disabled
1. Check the settings and the event logs.
2. Make sure that the Active Energy Manager feature is enabled in the
Setup utility. Select
System Settings
➙
Power
➙
Active Energy
Manager
➙
Capping Enabled
.
3. Update the UEFI firmware.
4. Update the IMM firmware.
IMM error codes in AMM
The integrated management module (IMM) consolidates the service processor functionality, video controller,
and remote presence capabilities in a single chip on the system board. The IMM monitors all components of
the blade server and posts events in the IMM event log. In addition, most events are also sent to the
advanced management module event log.
162
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...