Installation Leaflet

AnyBus-X

TM

Serial Server

Rev 1.1

HMS Industrial Networks

Power Supply

9-32 VAC/DC   (1.2VA)

Temperature range

Operating: 0-55 °C

Storage: -25 – 75 °C

Humidity range

5-95% RH, non-condensing

Mounting option

DIN rail (EN 50022)

CE certification

According to EN 50 081-2:1993 and EN 61000-6-2:1999

Dimensions

H57,7mm x W70.0mm x D86,0mm

Technical details

Configuration

About the AnyBus IPconfig utility and SerialIP COM-port redirection software

The AnyBus IP config utility is a PC-based configuration utility to set TCP/IP network settings in the AnyBus-X. This utility has the ability to scan the 

Ethernet network for connected AnyBus-X devices and let the user set IP-address, net mask, gateway, DNS and hostname for each unit. The SerilIP 

COM-port redirection software is necessary during operation to create the virtual COM-port(s) in the PC. It handles communication with the Serial 

Server.

Installation Procedure

Go to www.anybus.com and choose Support -> Anybus-X ->  Ethernet Virtual COMport -> RS232 COMport 

 

1.  Download and install the self-extracting installation package for AnyBus IPconfig

 

2.  Download and install the self-extracting installation package for SerialIP (use port 7000 and desired IP address)

 

3.  If needed download the “SerialIP Quick start Guide” to learn how to set up SerialIP

Scanning for connected devices

First ensure that you have connected the AnyBus-X units you want to install on the same Ethernet network as the PC is connected to. Use standard 

Ethernet cables, straight-through or cross-over cable depending on how you connect to the device. 

When the AnyBus IP config utility is started, it will scan the Ethernet network for AnyBus-X devices. All detected devices will be presented in a list in 

the main window. If you want to force a new scan for devices, you can press the “Scan” button.

Changing IP settings

To change the IP settings on a detected device, double-click on the device you want to configure in the list of devices. This will open up a dialog where 

you can enter the desired IP configuration.

The default password for authentication of the new settings is “

admin

”.

Pressing “Set” will cause the NetBiter device to reboot and after that the new settings will be enabled.

!

 

You can test the new settings by opening a web-browser and enter the IP you just selected.

If you selected DHCP and want to know what IP your device have been assigned, you can do a new scan with the AnyBus IP 

config utility to view the new network configuration information.

!

 

NOTE! Do not select the DHCP option if you don’t have a DHCP server available on the network.