LED
Status
Description
Action
Solid off
The system fans are operating
correctly.
3
System fan error LED
Solid on (amber)
One or more system fans are
running at low speed or have
been removed.
Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 209.
Note:
To identify the failing
system fans, check the status
LEDs on the system board. See
“System board LEDs” on page
56.
Solid off
The server is running at a normal
temperature.
4
Ambient temperature
limit LED
Solid on (amber)
The ambient temperature is below
7°C (44.6°F) or over 40°C (104°F).
Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 209.
Solid off
The power supply is working
correctly.
5
Power supply error
LED
Solid on (amber)
The power supply is likely to fail
or has failed.
Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 209.
Note:
To identify the failing power
supply, check the status LED
near the power cord connector
on the redundant power supply.
Rear view of the server
This topic provides information to help you locate the connectors and components on the rear of your server.
Chapter 3
.
Product overview
21
Summary of Contents for 70B4
Page 16: ...4 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 94: ...82 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 220: ...208 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 230: ...218 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 244: ...232 ThinkServer TD340 User Guide and Hardware Maintenance Manual ...
Page 245: ......
Page 246: ......