Appendix
179
D
AXIS
20.1
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
AXIS 50.1 W
D
Appendix
Manual adjustment of the drop point on the AXIS 50.1 W
(only in event of an electrical fault)
D.1
Deactivating the actuator control
The actuators, which are electrically operated for drop point adjustment, must be
disconnected prior to manual adjustment of the drop point.
NOTICE
If the drop point can no longer be electrically actuated it is adjusted manually.
1.
Disconnect the adjusting rod
from the adjustment centre
on both sides
. Remove the
pin to do this.
Figure 39:
Remove the pin
2.
Push rod to the side.
3.
Put pin back into the yoke
and lock.
Figure 40:
Remove rod