Maintenance and repair
139
C
AXIS
20.1
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
2.
Tighten the bolted connec-
tion with a torque wrench
(torque =
300 Nm
).
Figure 19:
Fasten the tie rod (in the rear of
the travelling direction under the
intermediate roof)
NOTICE
After tightening of the bolted connections with the torque wrench, the weighing
cells must be tared anew. Please follow the instructions in the chapter "Taring
the scales“ of the electronic control system operating manual.